Description
EPM.K (ЭПМ.К) cartridge membrane
elements are manufactured by a proprietary technology of Technofilter and are
close analogues of Pall's Ultipor and Nylaflo elements and Sartorius's Sartolon
element.
Material of Constructions
|
Membrane
|
Nylon 6
|
|
Support, Drainage
and End Caps
|
Polypropylene
|
|
Core and Cage
|
Polypropylene
|
|
O-rings
|
Silicone*
|
*optionally Viton or fluorine rubber Main
applications
-
In medicine and
biopharmaceutics: for removal of mechanical contaminants, clarification and
sterilization of parenteral and ophthalmological solutions, antibiotics,
cultural, bacterial and fermentative media, blood protein preparations, serum,
biological preparations and vaccines, vitamin and galena preparations, water
for injections.
-
In beverage industry: for
defertilization and cold sterilization of wine and beer, clarification of
distillery products, polishing filtration of vodkas, final filtration of
non-alcoholic beverages, mineral and bottled water, water for product
formulations and rinsing water.
-
In microelectronics, radio
engineering and biochemistry: for final filtration of deionized water,
photoresists, solvents and other media that are compatible with material of
construction.
-
In other industries: for
fine filtration of liquid media from particles 0.1 μm or more in size.
Main
size pore combinations of EPM.К elements
|
One-layer filters
|
Two-layer filters
|
|
Pore size, μm
|
Order code
|
Pore size, μm
|
Order code
|
| | | 0.45+0.10
| 045/010
|
|
0.20
|
020
|
0.20+0.20
|
020/020
|
|
0.45
|
045
|
0.45+0.20
|
045/020
|
0.65
| 065
| 0.65+0.45 | 065/045
| 0.80
| 080
| 0.80+0.65
| 080/065
| 1.0
| 100
| 3.0+0.80
| 300/080
| 3.0
| 300
| 3.0+1.0
| 300/100
|
Flow rate of EPМ.К elements as a function of
pressure using distilled water
Technical
and operating characteristics (for
250 mm high elements)
|
Element
designation
|
EPM.К
membrane cartridge element
|
|
Average
pore size, μm
|
0.1
|
0.2
|
0.45
|
0.65
|
0.8
|
1.0
|
1.2
|
3.0
|
|
Minimum
air bubble point, MPa
|
0.50
|
0.35
|
0.24
|
0.17
|
0.12
|
0.10
|
0.08
|
0.06
|
|
Maximum
operating pressure, MPa
|
0.5
|
|
Maximum
differential pressure, MPa
|
0.5
at 20°C; 0.20 at 70°C
|
|
Maximum
counterpressure, MPa
|
0.15
at 20°C
|
|
Maximum
operating temperature, °C
|
70
(80 for a short time)
|
|
Effective
filter area, m2
|
0.7,
one-layer; 0.6, two-layer
|
|
pH
range
|
3-14
|
|
Number
of sterilization cycles (by autoclaving) at P=0.1 MPa / t=121°±1°C for 30-45 min, no less than
|
20
|
Capacity
for retention of bacteria
Sterilizing
capacity of EPМ.К has been confirmed with respect to test microorganism Brevundimonas
Diminuta, stain PCI 818 (Pseudomonas Diminuta ATCC 19146, DSM 1635). The
level of microbiological load on the filter element complies with requirements
of the guideline of Association of producers of medical industry on
microbiological examination of filters for sterilization of liquids. EPМ.К
has been checked for retention of bacteria after 10 cycles of autoclaving at
121°C in the Pharmacopoeia mode.
Ordering Information
|
EPМ.К |
045/020 |
D1 |
250 |
М |
|
Grade
|
Removal Rating
|
Adapter types |
Nominal Length
|
Application
|
| |
|
|
|
|
| |
0.2 μm 0.45 μm 0.65 μm 0.80 μm 1.0 μm 3.0 μm |
A - Dead-end
cartridge, 44.5
mm adapter, disc
end cap,code: 27*, 3**, 0*** А1 - Dead-end cartridge, 44.5 mm adapter, fin
end
code:
26*(provisionally), 5***
А4 - Dead-end
cartridge, long 44.5 mm adapter, triple bayonet base at the bottom, fin end at the top, code: 28*
D1 - Dead-end cartridge, 56 mm adapter double bayonet base at
the bottom, fin end at the top, code:
25*,
7**, 7***
D - Dead-end
cartridge, 56 mm adapter, double bayonet base at
the bottom, disc end cap at the top В - In-line
cartridge, no adapter, code: 21*
В (SL) - In-line
cartridge, no
adapter, O-rings for Slime line
filter holders
|
100 = 100 mm
150 = 150 mm
250 = 250 mm (10 in.)
500 = 500 mm (20 in.)
750 = 750 mm (30 in.)
1000 = 1000 mm(40 in.) |
М = medical and biopharmaceutical.
P =
Food
industry
E=
Electronic
industry
|
*
Sartorius cartridge code; **
Pall cartridge code; *** Millipore cartridge
code
|
|